    Card GAP test of Comp A-5

    View/Open
    08-00469.pdf (1.088Mb)
    Date
    2008
    Author
    Nevstad, Gunnar Ove
    Metadata
    Show full item record
    Abstract
    Comp A-5 pressed to 95.4 %TMD (1.702 g/cm3) has been tested in NOL Card Gap test. The transition between no go and go was found to be 222-3 cards or 56.5 mm. This result indicates that Comp A-5 is relatively shock sensitive compared to more modern PBX compositions.
     
    Comp A-5 presset til 95.4% av TMD (1.702 g/cm3) er blitt testet i NOL Card GAP test. Overgangen mellom ingen reaksjon og detonasjon ble funnet å være 222-3 kort eller 56.5 mm. Dette resultatet tilsier at Comp A-5 har en relativ høy sjokkfølsomhet sammenlignet med mer moderne PBX komposisjoner.
     