Show simple item record

dc.contributor.authorHaakestad, Magnus Willum
dc.contributor.authorLamour, Tobias P.
dc.contributor.authorLeindecker, Nick
dc.contributor.authorMarandi, Alireza
dc.contributor.authorVodopyanov, Konstantin L.
dc.date.accessioned2017-11-16T08:36:31Z
dc.date.accessioned2017-11-17T11:34:30Z
dc.date.available2017-11-16T08:36:31Z
dc.date.available2017-11-17T11:34:30Z
dc.date.issued2013
dc.identifier.citationHaakestad MWH, Lamour, Leindecker N, Marandi A, Vodopyanov KL. Intracavity trace molecular detection with a broadband mid-IR frequency comb source. Journal of the Optical Society of America. B, Optical physics. 2013;30(3):631-640en_GB
dc.identifier.urihttp://hdl.handle.net/20.500.12242/810
dc.identifier.urihttps://ffi-publikasjoner.archive.knowledgearc.net/handle/20.500.12242/810
dc.descriptionHaakestad, Magnus Willum; Lamour, Tobias P.; Leindecker, Nick; Marandi, Alireza; Vodopyanov, Konstantin L.. Intracavity trace molecular detection with a broadband mid-IR frequency comb source. Journal of the Optical Society of America. B, Optical physics 2013 ;Volum 30.(3) s. 631-640en_GB
dc.description.abstractUltrasensitive detection of methane, isotopic carbon dioxide, carbon monoxide, formaldehyde, acetylene, and ethylene is performed in the spectral range 2.5–5 μm using intracavity spectroscopy in broadband optical parametric oscillators (OPOs). The OPOs were operated near degeneracy and synchronously pumped either by a mode-locked erbium (1560 nm) or thulium (2050 nm) fiber laser. A large instantaneous bandwidth of up to 800  cm −1 allows for simultaneous detection of several gases. We observe an effective path-length enhancement due to coherent interaction inside the OPO cavity and achieve part-per-billion sensitivity levels. The measured spectral shapes are in good agreement with a model that takes into account group delay dispersion across the broad OPO frequency band.en_GB
dc.language.isoenen_GB
dc.subjectTermSet Emneord::Spektroskopi
dc.subjectTermSet Emneord::Gass
dc.subjectTermSet Emneord::Deteksjon
dc.titleIntracavity trace molecular detection with a broadband mid-IR frequency comb sourceen_GB
dc.typeArticleen_GB
dc.date.updated2017-11-16T08:36:30Z
dc.identifier.cristinID1010725
dc.identifier.cristinID1010725
dc.identifier.doi10.1364/JOSAB.30.000631
dc.source.issn0740-3224
dc.source.issn1520-8540
dc.type.documentJournal article
dc.relation.journalJournal of the Optical Society of America. B, Optical physics


Files in this item

This item appears in the following Collection(s)

Show simple item record