Show simple item record

dc.contributor.authorLinge, Svein
dc.contributor.authorMardal, Kent-Andre
dc.contributor.authorHaughton, Victor
dc.contributor.authorHelgeland, Anders
dc.date.accessioned2017-10-11T07:46:37Z
dc.date.accessioned2017-10-12T11:38:13Z
dc.date.available2017-10-11T07:46:37Z
dc.date.available2017-10-12T11:38:13Z
dc.date.issued2013
dc.identifier.citationLinge S, Mardal K, Haughton V, Helgeland A. Simulating CSF flow dynamics in the normal and chiari I subarachnoid space during rest and exertion. American Journal of Neuroradiology. 2013;34(1):41-45en_GB
dc.identifier.urihttp://hdl.handle.net/20.500.12242/682
dc.identifier.urihttps://ffi-publikasjoner.archive.knowledgearc.net/handle/20.500.12242/682
dc.descriptionLinge, Svein; Mardal, Kent-Andre; Haughton, Victor; Helgeland, Anders. Simulating CSF flow dynamics in the normal and chiari I subarachnoid space during rest and exertion. American Journal of Neuroradiology 2013 ;Volum 34.(1) s. 41-45en_GB
dc.description.abstractBACKGROUND AND PURPOSE: CSF fluid dynamics in healthy subjects and patients with Chiari I have been characterized during rest with phase-contrast MR imaging and CFD. CSF flow velocities and pressures in the nonresting state have not been adequately characterized. We used computer simulations to study CSF dynamics during increased heart rates in the normal and Chiari I subarachnoid space. MATERIALS AND METHODS: Cyclic CSF flow was simulated for multiple cycles in idealized 3D models of the subarachnoid space for normal and Chiari I malformation subarachnoid spaces, with flow cycles corresponding to 80 or 120 heart beats per minute. Flow velocities and pressures were computed by the Navier-Stokes equations. Synchronous bidirectional flow and flow patterns were displayed in Star-CD and inspected visually. Peak velocities and pressure differences in the 2 models were compared for the 2-cycle frequencies. RESULTS: Elevating the cycle rate from 80 to 120 cpm increased peak superior-inferior pressure gradients (top-bottom) by just 0.01% in the normal model and 2% in the Chiari model. Corresponding average pressure gradients increased by 92% and 100%, respectively. In addition, in both models, the range of synchronous bidirectional flow velocities increased. Systolic velocities had smaller increases with faster cycling. For each cycle rate, peak and average pressure gradients in the Chiari model were greater than in the normal model by 11%–16%. CONCLUSIONS: Raising the cycle rate from 80 to 120 cpm increased superior-inferior average pressure gradients and the range of synchronous bidirectional flow velocities in the normal and Chiari I models.en_GB
dc.language.isoenen_GB
dc.titleSimulating CSF flow dynamics in the normal and chiari I subarachnoid space during rest and exertionen_GB
dc.typeArticleen_GB
dc.date.updated2017-10-11T07:46:37Z
dc.identifier.cristinID940647
dc.identifier.cristinID940647
dc.identifier.doi10.3174/ajnr.A3282
dc.source.issn0195-6108
dc.source.issn1936-959X
dc.type.documentJournal article
dc.relation.journalAmerican Journal of Neuroradiology


Files in this item

This item appears in the following Collection(s)

Show simple item record