Show simple item record

dc.contributor.authorKjerkreit, Gjermund Holmen_GB
dc.contributor.authorLippert, Espenen_GB
dc.date.accessioned2020-07-17T07:17:23Z
dc.date.accessioned2020-09-10T10:28:01Z
dc.date.available2020-07-17T07:17:23Z
dc.date.available2020-09-10T10:28:01Z
dc.date.issued2020-04-23
dc.identifier.citationKjerkreit G, Lippert E. A Monte Carlo approach to evaluate stray laser energy from the F-35 Lightning II. Proceedings of SPIE, the International Society for Optical Engineering. 2020en_GB
dc.identifier.urihttp://hdl.handle.net/20.500.12242/2764
dc.descriptionKjerkreit, Gjermund Holm; Lippert, Espen. A Monte Carlo approach to evaluate stray laser energy from the F-35 Lightning II. Proceedings of SPIE, the International Society for Optical Engineering 2020en_GB
dc.description.abstractThe F-35 Lightning II has a powerful combat laser designator operating at a wavelength and energy levels that are damaging to the human eye at a pulse level. Due to the faceted design of the Electro Optical Targeting System housing, unwanted Stray Laser Energy beams are emitted in uncontrolled directions. These beams are powerful enough to damage the human eye. Care must therefore be taken to ensure that observers on the ground are not unintentionally blinded. Using a general procedure where the hazard distance is determined by the length of the strongest Stray Laser Energy beam in any direction impedes the ability of the Royal Norwegian Air Force to train in Norway due to the size of the firing ranges and the limits to the maneuvering envelope. We have developed a Monte Carlo based model to determine the hazard "footprint" on the ground for typical flight patterns. The model incorporates several stochastic variables to catch the variations of an execution. The model also incorporates terrain data to evaluate if a beam will hit the actual terrain around a specified target. By running enough instances of the model, it is possible to generate an estimate for the probability of being hit by a beam for ground observers. Analysis has been performed for the unaided eye, binoculars of size 7x50mm and binoculars of size 20x120mm. By evaluating the risk level in accordance with guidelines provided by the The Norwegian Radiation and Nuclear Safety Authority, we have expanded the possibility for training using the combat laser in Norway.en_GB
dc.language.isoenen_GB
dc.subjectDatamodelleringen_GB
dc.subjectLasereen_GB
dc.subjectMonte Carlo-metodenen_GB
dc.titleA Monte Carlo approach to evaluate stray laser energy from the F-35 Lightning IIen_GB
dc.date.updated2020-07-17T07:17:23Z
dc.identifier.cristinID1817259
dc.source.issn0277-786X
dc.source.issn1996-756X
dc.subject.nsiVDP::Teknologi: 500
dc.subject.nsiVDP::Technology: 500
dc.type.documentJournal article
dc.relation.journalProceedings of SPIE, the International Society for Optical Engineering


Files in this item

This item appears in the following Collection(s)

Show simple item record